IBM C5050-408 Exam Preparation Questions For Best Result – Updated 2017

If you are in the hunt for a IBM C5050-408 exam dumps material that will bring you closer to success, 640-864.org is here to provide help in Worklight Foundation V6.2 C5050-408 certification exam. For several years now, we are the leading provider of C5050-408 exam questions for Worklight Foundation V6.2 Development Environment Set-up C5050-408 Exam. we have served over 70,000 IT professionals and helped them achieve their goals.

C5050-408 exam questions, C5050-408 PDF dumps; C5050-408 exam dumps:: https://www.dumpsschool.com/C5050-408-exam-dumps.html (74 Q&A) (New Questions Are 100% Available! Also Free Practice Test Software!)

Latest and Most Accurate IBM C5050-408 Dumps Exam Questions and Answers:

Version: 8.0
Question: 21

An application developer is required to use SMS notifications to send confirmation code to a mobile phone.
Which of the following is a valid entry in SMSConfig.xml that the application developer should use if the SMS gateway expects an HTTP post in the following format to forward SMS messages to a mobile phone:
http://hostname:13011/cgi-bin/sendsms?to=123456789&text=message text&username=user&password=pwd

A.

B.

C. gateway id=”gatewayID” hostname=”hostname” port=”13011” programName=”cgi-bin/sendsms”toParamName=”to” textParamName=”text”

D.

Answer: D

Explanation:
programName
Optional. The name of the program that the SMS gateway expects. For example, if the SMS gateway expects the following URI: Error! Hyperlink reference not valid. then programName=”sendsms”
The subelement is dependent on the SMS gateway. Each SMS gateway may have its own setof parameters. The number of subelements is dependent on SMS gateway-specific parameters. If an SMS gateway requires the user name and password to be set, then these parameters can be defined as subelements.
Each subelement has the following attributes: name
value
References: https://www.ibm.com/support/knowledgecenter/SSZH4A_6.2.0/com.ibm.worklight.deploy.doc/admin/ r_sms_gateway_config.html

Question: 22

An application developer is using Unstructured Supplementary Service Data (USSD) on a mobile application that is configured to send a USSD message with the information that is going to be stored on the server. After the information is stored, the application developer needs to configure a custom response message for the application that will send the text “Success” to the user.
Which is the correct code implementation that the application developer can use to return the expected response message to the user?

A. WL.Server.sendUSSDMessage(“Success”, “text/plain”, false))
B. WL.Server.sendUSSDResponse(“Success”, “text/plain”, true))
C. WL.Server.createUSSDMessage(“Success”, “text/plain”, false))
D. WL.Server.createUSSDResponse(“Success”, “text/plain”, true))

Answer: D

Explanation:
To send back a response:
WL.Server.createUSSDResponse(“This is my response”, “text/plain”, true))
References:
https://www.ibm.com/support/knowledgecenter/SSZH4A_6.2.0/com.ibm.worklight.dev.doc/devref/ c_ussd_support.html

Question: 23

New Updated C5050-408 Exam Questions C5050-408 PDF dumps C5050-408 practice exam dumps: https://www.dumpsschool.com/C5050-408-exam-dumps.html

An application developer is concerned about how many requests may hit the adapter being created. The developer wants to ensure that the adapter can handle enough requests, but yet not allow requests to overwhelm the system.
What can the application developer do to limit the number of requests that an adapter will handle?

A. In the web server configuration, specify number of requests for MaxClients.
B. In the application server configuration, specify the number concurrent requests for the servlet engine.
C. In the loadContraints element of the adapter XML file, specify the number of requests formaxConcurrentConnectionsPerNode.
D. In the connectionPolicy element of the adapter XML file, specify the number of requests formaxConcurrentConnectionsPerNode.

Answer: D

Explanation:
Tuning Back-end Connections
maxConcurrentConnectionsPerNode – The maximum number of concurrent requests that can be performed on the back-end application from the Worklight server node. The worklight server will create a thread pool with maxConcurrentConnectionsPerNode size for that purpose. This maxConcurrentConnectionsPerNode parameter is set in the adapter.xml in the connectivity entry.
References: https://www.ibm.com/developerworks/community/blogs/worklight/entry/tuning_worklight_server?lang=en

Question: 24

An application developer is attempting to update specific portions of a hybrid application by utilizing the direct update feature.
Which components can the application developer update using the direct update feature without having to rebuild and deploy a new binary of the application?

A. HTML, CSS, JavaScript
B. HTML, CSS, JavaScript, Java
C. HTML, CSS, JavaScript, Objective C
D. HTML, CSS, JavaScript, Version number

Answer: A

Explanation:
When you want to deliver a Worklight hybrid application that consists mainly of HTML5 with CSS and JavaScript, and you must change the hybrid part of the application to provide new features or to fix a defect, you do not have to ask the application users to update it on their devices. You can use the Worklight direct update mechanism to deploy new HTML with CSS and JavaScript for your application without changing the application version on the mobile device.
Incorrect:
Not D: Delivering a new version of native code
The main reason that you would want to deliver a new version of an application is probably because your application uses native code and you want to provide new features or deliver fixes that require changes in the native code. You might also need to provide a new native version of the application, even if your Worklight application is completely written by using web technologies, to accommodate new mobile operating systems supported only in later versions of IBM Worklight. You cannot use the direct update mechanism in either of these cases. You must build and deploy a new version of the application.
Reference: http://www.ibm.com/support/knowledgecenter/SSZH4A_6.2.0/com.ibm.worklight.dev.doc/devenv/ c_update_apps_wl_ac.html

Question: 25

The application developer needs to test the Worklight application on a remote server. In Worklight Studio, the application developer configures the remote server by right clicking on the {app_name} folder and selecting Run As > Build Settings and Deploy Target.
Which step does the application developer need to perform to ensure the server configuration changes are reflected in the application?

A. Run As > Run on Server
B. Run As > Build and Deploy
C. Run As > Apply Build Settings
D. Run As > Build All Environments

Answer: D

Explanation:
The Build Settings and Deploy Target dialog is used only to specify configurations and settings; clicking OK does not trigger a build. Any time that you make a modification with this dialog, you must rebuild your application and environments for your changes to take effect, by using the Run As > Build All Environments menu command.
References: https://www.ibm.com/support/knowledgecenter/SSZH4A_6.1.0/com.ibm.worklight.dev.doc/dev/ c_building_and_deploying_build_settings_deploy_target.html

Question: 26

Which one of the following correctly describes the content of the corresponding Worklight Application folder?

A. services folder – Contains client side services.
B. server folder – Contains libraries to be placed in external service servers.
C. bin folder – Contains project artifacts that are deployed to the Worklight Server.
D. externalServerLibraries folder – Contains references for application development and deployment.

Answer: C

Explanation:
The bin folder contains project artifacts that are deployed to MobileFirst Server.
Incorrect:
Not D: externalServerLibraries: Contains the libraries to be placed in external service servers and used for access token validation (by the service).
References:
https://developer.ibm.com/mobilefirstplatform/documentation/getting-started-6-3/hello-world/creating-your-firsthybrid-application/